The camera will be stuck in the bridge.
In this case, there are many environmental problems, the obstacles are blocked, the directions between the two bridges are crossed, the wireless interference in the vicinity is large, the aging of the network cable is aging, and the transmission power of the bridge is too large, resulting in a large delay.
Solution:
1. Check if there are obstacles blocking between the bridges
2. Try to ensure that the two bridges are vertically and horizontally installed, horizontally and horizontally, and not cross-mounted.
3. There are many pairs of bridges in the installed environment, and the interference is large. It is recommended to isolate more than 2 meters between the bridges, and debug different channels to avoid mutual interference. (The bridge of the dialing code can press the digital key to debug the channel. Such as: digital 0 corresponds to channel 1, digital 1 corresponds to channel 2, and so on)
4. Replace the network cable. The aging network cable may cause data transmission.
5. One-to-one or one-to-many bridges are close to each other, and there is no abnormality in the long distance. The wireless power of the main bridge can be debugged. The default is 100%, and it can be changed to 50% or 75%.